{"title":"Nu-Calgon Insulation","description":"","products":[{"product_id":"nu-calgon-4217-w3-cork-tape","title":"Nu-Calgon 4217-W3 Cork Tape","description":"\u003cstrong\u003eNu-Calgon 4217-W3 Cork Tape\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e2 inch x 1\/8 inch x 30 foot Roll\u003c\/strong\u003e\u003cbr\u003e\u003cp\u003eCork Insulation Tape was developed specifically for the air conditioning and refrigeration industry. Formulated and manufactured, to meet specific specifications as an insulating material for preventing sweating and condensation on refrigerant lines, cold pipes and other commercial refrigeration and air conditioning systems. It also can serve as an excellent insulator on hot pipes, wrapping valves, tees, fittings, gasketing material. Also used for sound-deadening material, \u003cstrong\u003eit can be applied at temperatures as low as -30ºF, as high as 200ºF, and won’t sag up to 350ºF.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eDeveloped to provide insulation on lines to meet the rigorous demands of today’s HVACR service engineers. Cork Tape remains flexible, and has excellent paper release, and adhesion strength to all surfaces.\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eDirections\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThis product must be used in accordance to the following directions by HVACR professionals only.\u003c\/strong\u003e\u003c\/p\u003e\u003col\u003e\n\u003cli\u003eCut end at an angle.\u003c\/li\u003e\n\u003cli\u003eStart end and coil loosely around the pipe.\u003c\/li\u003e\n\u003cli\u003eTighten coil.\u003c\/li\u003e\n\u003cli\u003eCut patches for valves, joints, etc.\u003c\/li\u003e\n\u003cli\u003ePress tightly and cover exposed pipe\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003eOne layer of tape will protect under most conditions. If pipe or outside temperatures are very low, or if humidities are very high, additional layers may be required. Contact manufacturer for additional engineering data.\u003c\/p\u003e","brand":"Nu-Calgon","offers":[{"title":"Default Title","offer_id":47344360620205,"sku":null,"price":19.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/4217W3.png?v=1787907241"},{"product_id":"nu-calgon-4219-12-foam-tite","title":"Nu-Calgon 4219-12 Foam-Tite","description":"\u003cstrong\u003eNu-Calgon 4219-12 Foam-Tite\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e2 inch x 1\/8 inch x 30 foot Roll\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cp\u003eFoam-Tite insulation Tape provides the service technician with a quality yet economical solution to one of the most common HVACR application problems: sweating or condensation on air conditioning, refrigeration, chilled water or other cold lines. Because of its excellent insulation properties, it can also be used on hot water lines for insulation against heat loss.\u003c\/p\u003e\u003cp\u003eKeeps cold lines cold and hot lines hot. It can be overlapped or the edges can be butted. The amount of tape that will be required and the style of wrap (over-lapped, butted or both) will depend upon relative humidity, ambient temperature and the temperature of the pipe to be covered. \u003cstrong\u003eService temperatures can be as low as -15ºF with a high continuous temperature of 160ºF.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eDirections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThis product must be used in accordance to the following directions by HVACR professionals only.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eApply Foam-Tite by removing release paper as the tape is spirally wrapped around the piping or fittings, and press firmly in place; avoid stretching.\u003c\/p\u003e\u003cp\u003ePressure-sensitive adhesive adhere firmly and forms a long lasting bond to metal surfaces.\u003c\/p\u003e\u003cp\u003eFor a faster and more efficient job, tape should be spiral-wrapped to obtain a 50% over-lap. Additional layers build up insulation to required thickness.\u003c\/p\u003e\u003cp\u003eTo insulate valves, tees, and fittings, cut small pieces of tape and press into place until all metal is covered.\u003c\/p\u003e\u003cp\u003eOverwrap with longer lengths for a durable and efficient job.\u003c\/p\u003e","brand":"Nu-Calgon","offers":[{"title":"Default Title","offer_id":47344361046189,"sku":null,"price":10.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/421912.png?v=1787907246"},{"product_id":"nu-calgon-61308-a-c-drain-sucker-kit","title":"Nu-Calgon 61308 A\/C Drain Sucker Kit","description":"\u003cstrong\u003eNu-Calgon 61308 A\/C Drain Sucker Kit\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCleanAir# CADS1\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cspan\u003eA\/C condensate drain pan overflows are a very common and costly service problem. The overflows are caused by slime and sludge that builds up and clogs the drain line. The A\/C Drain Sucker quickly removes the clog and excess water, resolving the overflow problem. The kit also includes PurCool® Shock Tablets to clean and treat the remaining slime and sludge in the pan and lines, as well as a PurCool® Pan Strip to provide months of preventive treatment and free flowing drains.\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cp\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eDirections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size: x-small;\"\u003e\u003cstrong\u003eTo Suction a Clogged Condensate Drain:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003col\u003e\n\u003cli\u003eUsing the special black connector fittings, connect the two gray hoses to the top (suction) and bottom (discharge) fittings on the drain sucker pump body making sure to push the gray hose snugly into the pump fitting and then slide the black connector fitting tightly over the hose and pump fitting.\u003c\/li\u003e\n\u003cli\u003eConnect the barbed plastic fitting on the 3\/4” PVC coupling to the other end of the gray hose that is connected to the top (suction) fitting of the pump body.\u003c\/li\u003e\n\u003cli\u003eSlip the 3\/4” PVC coupling over the 3\/4” PVC condensate drain outlet where it terminates.\u003c\/li\u003e\n\u003cli\u003eSet the outlet of the discharge (bottom) hose where it can safely discharge water.\u003c\/li\u003e\n\u003cli\u003eBegin pumping to remove clog and excess condensate water.\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003e\u003cspan style=\"font-size: x-small;\"\u003e\u003cstrong\u003eTo Blow-Out a Clogged Condensate Drain Pan:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003col\u003e\n\u003cli\u003eConnect hoses to the pump body as described above.\u003c\/li\u003e\n\u003cli\u003eConnect the outlet of the gray hose from the pump bottom (discharge) to the plastic barbed fitting on the black rubber cone fitting.\u003c\/li\u003e\n\u003cli\u003ePush the black rubber cone fitting snugly into 3\/4” PVC condensate drain outlet where it terminates.\u003c\/li\u003e\n\u003cli\u003eBegin pumping to build pressure and break up clog.\u003c\/li\u003e\n\u003cli\u003eThis procedure can also be done from the condensate drain pan at the A\/C unit.\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003e\u003cspan style=\"font-size: x-small;\"\u003e\u003cstrong\u003eCleaning \u0026amp; Treating A\/C Condensate Drain Pans:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003eOnce drain clogs are cleared, use the tablets from the PurCool Shock Pack to clean and treat the fouled drain pan. Use the yellow PurCool Pan Strip, per the package instructions, for long term prevention of drain clogs and overflows. Pan strips will not float and provide up to six months of time release treatment.\u003c\/p\u003e","brand":"Nu-Calgon","offers":[{"title":"Default Title","offer_id":47344366518445,"sku":"61308","price":53.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/DrainSuckerPkg.png?v=1787907282"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/collections\/Insulation_20main.png?v=1787914284","url":"https:\/\/www.bostonheatingsupply.com\/collections\/insulation.oembed","provider":"Boston Heating Supply","version":"1.0","type":"link"}