{"title":"Tjernlund Gas Side Wall Vent Systems","description":"\u003cdiv style=\"text-align: center;\"\u003e\n\u003cimg border=\"0px\" align=\"\" style=\"width: 442px; height: 100px;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TjernlunLogo2.jpg\"\u003e\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cspan style=\"font-family: Verdana; font-size: 10pt;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eSide Wall Vent Systems save time and money and are excellent for electric to gas\/oil, renovations, new construction or for replacing deteriorated chimneys.\u003cbr\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 10pt;\"\u003e \u003cbr\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 10pt;\"\u003eSide wall venting saves costly materials and labor on two, three or more story runs.  It also increases living space by cutting out interior chases.  Proven safety interlocks assure proper exhaust, a feature conventional chimneys do not offer in today's homes and buildings.\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e \u003cbr\u003e \u003ca style=\"font-weight: bold;\" href=\"http:\/\/www.tjernlund.com\/Sizing\/default.htm\" target=\"_blank\"\u003eSIDE WALL VENT SYSTEM SELECTION TOOL\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cbr\u003e","products":[{"product_id":"tjernlund-gpak-1-gas-heater-vent-system","title":"Tjernlund GPAK-1 Gas Heater Vent System","description":"\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003e\u003cspan style=\" font-size: 12pt;\"\u003eGPAK* gas vent packages combine the Power Venter, VH1-4 Vent Hood and 4\" Barometric Draft Control to make it easier for the wholesaler to inventory and the contractor to order.  GPAK* Series Power Venters include a factory prewired Fan Proving Switch and non-adjustable 45 second, post-purge Relay\/Timer to purge the vent system of residual flue gases after burner cycle has completed.  AGA Certification and package concept make the GPAK a popular Side Wall Venting solution.\u003c\/span\u003e\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cspan style=\"font-weight: bold;  font-size: 12pt;\"\u003eSPECIFICATIONS:\u003cbr\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cul style=\"\"\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003eModel Number: GPAK-1\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003eRelay: 24\/115V Switching Relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003eFan Proving Switch: 3FLA, 18 LRA@120 VAC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003eMotor Specifications: 115V, 60 Hz, 3000 RPM, 95 Watts, 1.26 Amps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003eVent Pipe Diameter: 4\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003eBTU\/hr Input: 100,000\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-size: 12pt; color: #000000; \"\u003e \u003cbr\u003e \u003cspan style=\"font-weight: bold; font-size: 12pt;\"\u003eRESOURCES:\u003cbr\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cul style=\"\"\u003e\n\u003cli style=\"\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8500370.pdf\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eTjernlund GPAK-1 - Specifications\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003c\/span\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8504027.pdf\"\u003eTjernlund VH1-4 Vent Hood - Specifications\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8504013.pdf\" style=\"\"\u003eTjernlund GPAK-1 - Installation \u0026amp; Operation Manual\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cbr\u003e \u003cimg border=\"0px\" align=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Tjernlund_-_GPAK1_-_Diagram.jpg?v=1788404080\" alt=\"\"\u003e\u003cbr\u003e \u003c\/span\u003e","brand":"Tjernlund","offers":[{"title":"Default Title","offer_id":47344106307757,"sku":"5912","price":699.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TjernlundGPAK.gif?v=1787917934"},{"product_id":"tjernlund-hs1-side-wall-power-venter","title":"Tjernlund HS1 Side Wall Power Venter","description":"\u003cspan style=\"font-size: 12pt; \"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eThe HS1 is used for side wall venting residential\/light commercial natural gas, LP or oil fired equipment including: Furnaces, boilers, water heaters and unit heaters. All models feature the new UC1 Universal Control and a diaphragm Fan Proving Switch safety interlock which will shut down the heating equipment if a venting malfunction occurs. Built-in adjustable damper also allows regulation for maximum combustion efficiency. UC1 Universal Control features include; adjustable pre and post-purge settings, LED Status\/diagnostic indicators, Fan Prover switch monitoring. Interlocks with any 24-120 VAC burner control circuit and also includes \"dry\" contact actuation option. Easily interlock multiple appliances with our MAC-Series multiple appliance controls.\u003c\/span\u003e\u003cspan style=\"font-weight: bold; font-size: 12pt;\"\u003e\u003cbr\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cbr\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-weight: bold;  font-size: 12pt;\"\u003eRESOURCES\u003c\/span\u003e\u003cbr style=\"\"\u003e \u003c\/span\u003e\u003cul style=\"\"\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8506001b.pdf\"\u003eTjernlund HS1 Power Venter Specifications\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8504106C.PDF\"\u003eTjernlund HS1 Power Venter Installation \u0026amp; Operation Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 12pt;\"\u003e\u003c\/span\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8504107d.PDF\"\u003eTjernlund UC1 Installation Instructions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Tjernlund_-_HSJ-HS1-HS2_-_Table.jpg?v=1788404081\" style=\"width: 650px; height: 499px;\" align=\"\" border=\"0px\"\u003e\u003cbr\u003e \u003cbr\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Tjernlund_-_HS1_-_Diagram.jpg?v=1788404080\" alt=\"\" style=\"width: 679px; height: 394px;\" align=\"\" border=\"0px\"\u003e","brand":"Tjernlund","offers":[{"title":"Default Title","offer_id":47344106340525,"sku":"19277","price":399.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TjernlundHSJ.1.jpg?v=1787902747"},{"product_id":"tjernlund-hsj-side-wall-power-venter","title":"Tjernlund HSJ Side Wall Power Venter","description":"\u003cspan style=\"font-size: 12pt; \"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eThe HSJ is used for side wall venting residential\/light commercial natural gas, LP or oil fired equipment including: Furnaces, boilers, water heaters and unit heaters. All models feature the new UC1 Universal Control and a diaphragm Fan Proving Switch safety interlock which will shut down the heating equipment if a venting malfunction occurs. Built-in adjustable damper also allows regulation for maximum combustion efficiency. UC1 Universal Control features include; adjustable pre and post-purge settings, LED Status\/diagnostic indicators, Fan Prover switch monitoring. Interlocks with any 24-120 VAC burner control circuit and also includes \"dry\" contact actuation option. Easily interlock multiple appliances with our MAC-Series multiple appliance controls.\u003c\/span\u003e\u003cspan style=\"font-weight: bold; font-size: 12pt;\"\u003e\u003cbr\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cbr\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-weight: bold;  font-size: 12pt;\"\u003eRESOURCES\u003c\/span\u003e\u003cbr style=\"\"\u003e \u003c\/span\u003e\u003cul style=\"\"\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8506001b.pdf\"\u003eTjernlund HSJ Power Venter Specifications\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8504106C.PDF\"\u003eTjernlund HSJ Power Venter Installation \u0026amp; Operation Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8504107d.PDF\"\u003eTjernlund UC1 Installation Instructions\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cimg border=\"0px\" align=\"\" style=\"width: 650px; height: 499px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Tjernlund_-_HSJ-HS1-HS2_-_Table.jpg?v=1788404081\" alt=\"\"\u003e\u003cbr\u003e \u003cbr\u003e \u003cimg border=\"0px\" align=\"\" style=\"width: 663px; height: 376px;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Tjernlund_-_HS1_-_Diagram.jpg?v=1788404080\"\u003e\u003cbr\u003e","brand":"Tjernlund","offers":[{"title":"Default Title","offer_id":47344106373293,"sku":"21333","price":359.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TjernlundHSJ.jpg?v=1787902752"},{"product_id":"tjernlund-hs2-side-wall-power-venter","title":"Tjernlund HS2 Side Wall Power Venter","description":"\u003cspan style=\"font-size: 12pt; \"\u003e\u003cspan style=\"font-size: 12pt; color: #000000;\"\u003eThe HS2 is used for side wall venting residential\/light commercial natural gas, LP or oil fired equipment including: Furnaces, boilers, water heaters and unit heaters. All models feature the new UC1 Universal Control and a diaphragm Fan Proving Switch safety interlock which will shut down the heating equipment if a venting malfunction occurs. Built-in adjustable damper also allows regulation for maximum combustion efficiency. UC1 Universal Control features include; adjustable pre and post-purge settings, LED Status\/diagnostic indicators, Fan Prover switch monitoring. Interlocks with any 24-120 VAC burner control circuit and also includes \"dry\" contact actuation option. Easily interlock multiple appliances with our MAC-Series multiple appliance controls.\u003c\/span\u003e\u003cspan style=\"font-weight: bold; font-size: 12pt;\"\u003e\u003cbr\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cbr\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-weight: bold;  font-size: 12pt;\"\u003eRESOURCES\u003c\/span\u003e\u003cbr style=\"\"\u003e \u003c\/span\u003e\u003cul style=\"\"\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8506001b.pdf\"\u003eTjernlund HS2 Power Venter Specifications\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8504106C.PDF\"\u003eTjernlund HS2 Power Venter Installation \u0026amp; Operation Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8504107d.PDF\"\u003eTjernlund UC1 Installation Instructions\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cimg border=\"0px\" align=\"\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Tjernlund_-_HSJ-HS1-HS2_-_Table.jpg?v=1788404081\" style=\"width: 650px; height: 499px;\"\u003e\u003cbr\u003e \u003cbr\u003e \u003cimg border=\"0px\" align=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Tjernlund_-_HS2_-_Diagram.jpg?v=1788404080\" alt=\"\" style=\"width: 667px; height: 434px;\"\u003e","brand":"Tjernlund","offers":[{"title":"Default Title","offer_id":47344106406061,"sku":"17877","price":599.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TjernlundHSJ.2.jpg?v=1787902752"},{"product_id":"tjernlund-hs3-commercial-side-wall-power-venter","title":"Tjernlund HS3 Commercial Side Wall Power Venter","description":"\u003cspan style=\" font-size: 12pt; color: #000000;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eThe HS3 is used for side wall venting commercial natural gas or LP fired equipment including: boilers, water heaters and unit heaters.  All models feature the new UC1 Universal Control and a diaphragm Fan Proving Switch safety interlock which will shut down heating equipment if a venting malfunction occurs.  UC1 Universal Control features include; adjustable pre and post-purge settings, LED Status\/diagnostic indicators, Fan Prover switch monitoring.  Interlocks with any 24-120 VAC burner control circuit and also includes \"dry\" contact actuation option.  Easily interlock multiple appliances with our MAC-Series multiple appliance controls.\u003c\/span\u003e\u003cspan style=\"font-size: 12pt;\"\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 12pt;\"\u003eAllows for a significant reduction in vent pipe diameter to save on costly materials and labor.  Built-in adjustable damper also allows regulation for maximum combustion efficiency.\u003cbr\u003e \u003cbr style=\"font-weight: bold;\"\u003e \u003cspan style=\"font-weight: bold;\"\u003eRESOURCES\u003cbr\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8506002b.pdf\"\u003eTjernlund HS3 Specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8504111C.PDF\"\u003eTjernlund HS3 Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8500004.pdf\"\u003eTjernlund UC1 Universal Control Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.tjernlund.com\/Tjernlund_8504107d.PDF\"\u003eTjernlund UC1 Universal Control Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e \u003cimg border=\"0px\" align=\"\" style=\"width: 878px; height: 541px;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Tjernlund_-_HS3_-_Diagram.jpg?v=1788404080\"\u003e","brand":"Tjernlund","offers":[{"title":"Default Title","offer_id":47344106438829,"sku":"14890","price":989.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TjernlundHSJ.3.jpg?v=1787902752"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/collections\/Tjernlund_20-_20HS1.jpg?v=1787914192","url":"https:\/\/www.bostonheatingsupply.com\/collections\/tjernlundgassidewallpowerventsystems.oembed","provider":"Boston Heating Supply","version":"1.0","type":"link"}