{"product_id":"fernox-tf1-total-filter","title":"Fernox TF1 Total Filter","description":"\u003ca href=\"https:\/\/fxdoc.s3.eu-west-2.amazonaws.com\/en\/Prevent_boiler_breakdown_-_contractors_leaflet_-_no_crops.pdf\" target=\"_blank\"\u003ePrevent boiler breakdown – Contractors leaflet\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/fxdoc.s3.eu-west-2.amazonaws.com\/en\/Using+Fernox+Express+Chemicals+with+the+TF1+Filter+Range.pdf\" target=\"_blank\"\u003eHow to dose Fernox Express via a Fernox TF1 Filter\u003c\/a\u003e\u003ca href=\"https:\/\/fxdoc.s3.eu-west-2.amazonaws.com\/en\/Prevent_boiler_breakdown_-_contractors_leaflet_-_no_crops.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/fxdoc.s3.eu-west-2.amazonaws.com\/en\/TF1_Total_Filter_-_Fernox.pdf\" target=\"_blank\"\u003eFernox TF1 Total Filter Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/fxdoc.s3.eu-west-2.amazonaws.com\/en\/Prevent_boiler_breakdown_-_contractors_leaflet_-_no_crops.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/fxdoc.s3.eu-west-2.amazonaws.com\/en\/TF1_Range_Installers_Leaflet_UK-v4-1.pdf\" target=\"_blank\"\u003eTF1 Total and Compact Filter Range\u003c\/a\u003e\u003ca href=\"https:\/\/fxdoc.s3.eu-west-2.amazonaws.com\/en\/Prevent_boiler_breakdown_-_contractors_leaflet_-_no_crops.pdf\" target=\"_blank\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/a\u003e\u003cdiv class=\"elementor-element elementor-element-db02cfc elementor-widget elementor-widget-text-editor\" data-id=\"db02cfc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\u003cdiv class=\"elementor-widget-container\"\u003e\u003cdiv class=\"elementor-text-editor elementor-clearfix\"\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eProduct Overview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eThe TF1 Total Filter is constructed from a high strength, glass reinforced polymer, which has good hydrolysis resistance as well as high resistance to strain and abrasion. The polymer is compatible with glycols and additives and is suitable for use in central heating systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eThe TF1 Total Filter has been designed to ensure there is minimal pressure loss whilst continuing to maintain a high collection efficiency. The unique hydrocyclonic action, magnet assembly, and area of low flow have all been engineered to allow the filter to capture a range of system contaminates, whilst not impacting the rest of the heating system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eThe TF1 Total Filter utilises a range of high-quality component parts that ensure the filter offers optimum performance. All isolation valves are designed to allow users to operate them easily by hand, whilst also providing a secure connection to the system and a robust service point. The magnet is manufactured using a premium grade of neodymium, enabling a high-efficiency capture rate, as well as a robust filtration medium that will ensure a continued and consistent level of collection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cdiv class=\"elementor-widget-container\"\u003e\u003cdiv class=\"elementor-text-editor elementor-clearfix\"\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cbr\u003eApplication, Fitting \u0026amp; Dosing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cspan style=\"font-size: small;\"\u003eThe TF1 Total Filter can be connected directly on to the pipework using the valve fittings provided. The TF1 Total Filter can be installed in any one of 24 separate orientations enabled by its unique inlet\/outlet mechanism. The TF1 Total Filter (UK patent granted No. 2448232) is a revolutionary in-line filter, which combines Hydrocyclonic action with specially designed magnet assemblies, to remove both magnetic and non-magnetic contaminants from system water and contain safely within the filter before removal.\u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003eThe TF1 Total Filter can be installed on vertical or horizontal pipework, in accordance with the flow direction indicated by the arrow on the manifold. Ideally the filter should be fitted on the return to the boiler and can be installed at up to 45 from the vertical position if space or head height is restricted.\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cbr\u003e\u003cspan style=\"text-decoration: underline;\"\u003ePerformance\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cdiv class=\"elementor-element elementor-element-1e6a559 elementor-widget elementor-widget-text-editor\" data-id=\"1e6a559\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\u003cdiv class=\"elementor-widget-container\"\u003e\u003cdiv class=\"elementor-text-editor elementor-clearfix\"\u003e\n\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eSuitable Fluids:\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eWater\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eInhibited Glycol Solutions\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eFernox Chemical Range \/ System Additives\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eMaximum Percentage of Glycol – 50%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eMaximum Working Pressure – 50 L\/min\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eMaximum Working Temperature – 100C\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eCapture Rate – Up to 100% of system contaminates\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eOperating Principle – Contaminated water enters the filter via the manifold, carrying a variety of system debris and particulate matter held in suspension. This debris, including ferrous impurities such as Magnetite, move through the manifold and into the main body of the filter.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eThe TF1 Total Filter utilises Hydrocyclonic filtration. A Hydrocyclone is a static device that applies centrifugal force to a liquid mixture to promote the separation of particles.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eThe Hydrocyclonic action has been designed to convert incoming liquid velocity into rotary motion. As water enters the filter, it spins around and down the outside of the filter, carrying particles with it. The shape of the filter has been designed to create a dead zone at the bottom where heavier particles are deposited.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eThe Hydrocyclone in the TF1 Total Filter has been optimised in order to allow for the maximum filtration ability of both magnetic and non-magnetic material.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eOnce the flow of water has reached the bottom of the filter, water moves back up through the centre of the TF1 Total Filter, carrying particles over the magnet sheath, promoting further magnetic filtration and enhancing the collection capabilities of the filter.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003eAny dirt collected within the filter can then be discharged by removing the magnet from the sheath and opening the drain valve. This procedure is shown in the cleaning guide and does not require system shutdown, or the filter to be disassembled.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/ri3DqP1FB9U\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e","brand":"Fernox","offers":[{"title":"Default Title","offer_id":47344145891501,"sku":"60003","price":299.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/60003-TF1-Total-Filter.jpg?v=1787903722","url":"https:\/\/www.bostonheatingsupply.com\/products\/fernox-tf1-total-filter","provider":"Boston Heating Supply","version":"1.0","type":"link"}