{"product_id":"honeywell-r8182d111-protectorelay-hydronic-heating-control","title":"Honeywell R8182D111 Protectorelay® \/ Hydronic Heating Control","description":"\u003cdiv class=\"overview\"\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eImmersion type Aquastat controller and oil burner primary control provides high limit and low limit\/circulator control for oil-fired hydronic heating systems.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"features\"\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse in intermittent ignition applications.\u003c\/li\u003e\n\u003cli\u003eCapable of zone control with zone valves.\u003c\/li\u003e\n\u003cli\u003eCirculator zone control with ZC and ZR terminals on R8182D,E,H,J. 8*Flame failure during the running cycle results in a 45 second attempt to restart.\u003c\/li\u003e\n\u003cli\u003eIf unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted.\u003c\/li\u003e\n\u003cli\u003eR8182D,E,F mount directly on burner; R8182H,J mount on 4 x 4 in. junction box and include 5 ft (1.5 m) armored capillary with remote sensor.\u003c\/li\u003e\n\u003cli\u003eC554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eHazmat Information:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e UN 1294, TOLUENE, 3, II\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eDimensions (in.):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 7 1\/8 in. high x 5 1\/4 in. wide x 3 7\/16 in. deep.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eDimensions (mm):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 181 mm high x 133 mm wide x 87 mm deep.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMaximum Safe Operating Pressure (psi):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 200 psi on immersion well; 100 psi direct immersion.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMaximum Safe Operating Pressure (kPa):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 1378 kPa on immersion well; 90 kPa direct immersion.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cst1:place style=\"font-size: 12px;\"\u003e\u003cst1:placename\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/st1:placename\u003e\u003cb\u003e \u003cst1:placetype\u003eRange\u003c\/st1:placetype\u003e\u003c\/b\u003e\u003c\/st1:place\u003e\u003cb style=\"font-size: 12px;\"\u003e (F):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Maximum--250 F at element\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eTemperature Range (C):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Maximum--121 C at element\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eIncludes:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and vertical case.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMounting:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Horizontal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eFrequency:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 60 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eApprovals, Underwriters Laboratories Inc.:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e UL Listed: File No. listed: MP268, Vol. 3,4 (R8182D,E,F), Vol. 37 (R8182H,J), Sec. 1.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eApprovals, CSA:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Certified: File No. LR95329-1\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eTradeline Value:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Tradeline\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eOperating \u003cst1:place\u003e\u003cst1:placename\u003eHumidity\u003c\/st1:placename\u003e \u003cst1:placetype\u003eRange\u003c\/st1:placetype\u003e\u003c\/st1:place\u003e (% RH):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 0 to 95% RH, non-condensing\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003ePower Consumption:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 9 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eVoltage:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 120 Vac\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eOperating \u003cst1:place\u003e\u003cst1:placename\u003eTemperature\u003c\/st1:placename\u003e \u003cst1:placetype\u003eRange\u003c\/st1:placetype\u003e\u003c\/st1:place\u003e (F):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e High Limit-- 130 F to 240 F; Low Limit-- 110 F to 220 F\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eOperating Temperature Range (C):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e High Limit-- 54 C to 116 C; Low Limit-- 43 C to 104 C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eDifferential Temperature (F):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e High limit: 10 F fixed; Low limit\/circulator: 10 F to 25 F adj.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eTiming:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Safety Switch-- 45 sec\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eAnticipator Setting:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 0.2 A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eInsulation Depth (in.):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 1 1\/2 in.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eInsulation Depth (mm):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 38 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eElectrical Ratings, Ignition:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 360 VA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eElectrical Ratings, Burner:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e At Full Load-- 4.4 A @ 120 Vac; At Locked Rotor-- 26.4 A @ 120 Vac\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47344074686637,"sku":"R8182D1111","price":753.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Honeywell_R8182d111_combinationprotectorrelayhydronicheatingcontrolw.highlimit_5244.jpg?v=1787917782","url":"https:\/\/www.bostonheatingsupply.com\/products\/honeywell-r8182d111-protectorelay-hydronic-heating-control","provider":"Boston Heating Supply","version":"1.0","type":"link"}