{"product_id":"honeywell-r8184g4009-protectorelay-oil-burner-control","title":"Honeywell R8184G4009 Protectorelay Oil Burner Control","description":"\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003eHoneywell R8184G4009 Protectorelay Oil Burner Control w\/ 45 sec. safety timing, alarm outputs, and manual safety switch\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cdiv class=\"overview\"\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eProvides automatic, nonrecycling control of an intermittent ignition oil burner system.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"features\"\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat.\u003c\/li\u003e\n\u003cli\u003eSolid state flame sensing circuit.\u003c\/li\u003e\n\u003cli\u003eLED on terminal strip indicates system lockout (available on some models).\u003c\/li\u003e\n\u003cli\u003eRemote lockout indication (available on some models).\u003c\/li\u003e\n\u003cli\u003eEnclosed safety switch with external reset button.\u003c\/li\u003e\n\u003cli\u003eManual trip lever opens safety switch for system maintenance.\u003c\/li\u003e\n\u003cli\u003eMounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing.\u003c\/li\u003e\n\u003cli\u003eC554A Cadmium Sulfide Flame Detector and 24 Vac thermostat required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eSpecifications:\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eDimensions (in.):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 4 3\/8 in. high x 4 1\/8 in. wide x 2 1\/2 in. deep\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eDimensions (mm):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 111 mm high x 104 mm wide x 64 mm deep\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cst1:place style=\"font-size: 12px;\"\u003e\u003cst1:placename\u003e\u003cb\u003eTemperature\u003c\/b\u003e\u003c\/st1:placename\u003e\u003cb\u003e \u003cst1:placetype\u003eRange\u003c\/st1:placetype\u003e\u003c\/b\u003e\u003c\/st1:place\u003e\u003cb style=\"font-size: 12px;\"\u003e (F):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e -40 F to +130 F\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eTemperature Range (C):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e -40 C to +54 C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eComments:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e With LED for lockout indication, and manual trip lever on safety switch to assure burner shutdown during servicing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMounting:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e For mounting on a standard 4 in. X 4 in. junction box or direct mounting on burner housing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eApprovals, Underwriters Laboratories Inc.:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e UL Component Recognized; File no. MP268, Vol. 35 Sec. 1,3\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eApprovals, CSA:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e CSA Certified; File no. LR95329-1\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eIgnition Type:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Intermittent\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eTiming, Safety Switch:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 45 sec.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eElectrical Ratings, Contacts (full load): 7\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e.4 A @ 120 Vac; 3.7 a @ 240 Vac\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eElectrical Ratings, Contacts (locked rotor):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 44.4 A @ 120 Vac; 22.2 A @ 240 Vac\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eAlarm Load Ratings (pilot duty):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 75 VA @ 120\/240 Vac, 50-60 Hz; 25 VA @ 24V, 50-60 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eAlarm Load Ratings (resistive):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 1.5 A @ 120\/240V, 50-60Hz; 3 A @ 24 V, 50-60 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47344074719405,"sku":"R8184G4009","price":125.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Honeywell_R8184G4009_protectorelayoilburnercontrolw.45sec.lockoutside_3836.jpg?v=1787917783","url":"https:\/\/www.bostonheatingsupply.com\/products\/honeywell-r8184g4009-protectorelay-oil-burner-control","provider":"Boston Heating Supply","version":"1.0","type":"link"}