{"product_id":"honeywell-v8043e1004-1-2-sweat-zone-valve","title":"Honeywell V8043E1004 1\/2\" Sweat Zone Valve","description":"Honeywell V8043E1004 1\/2\" Sweat Zone Valve\u003cbr\u003e\u003cspan\u003e24V 1\/2 in Sweat N.C. Zone Valve\u003c\/span\u003e\u003cbr\u003e\u003cdiv class=\"overview\"\u003e\n\u003ch2\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eOverview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eTwo-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"features\"\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored.\u003c\/li\u003e\n\u003cli\u003eAll models may be installed without disassembling the valve.\u003c\/li\u003e\n\u003cli\u003eCompact construction for easy installation.\u003c\/li\u003e\n\u003cli\u003eComplete powerhead may be removed or replaced without breaking plumbing line connections or draining the system.\u003c\/li\u003e\n\u003cli\u003eActuator motor may be replaced without removing the valve body or draining the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eApplication:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Hydronic Control\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eDimensions (in.):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 4 in. high x 3-1\/2 in. wide x 2 3\/8 in. deep\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eDimensions (mm):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 101 mm high x 90 mm wide x 60 mm deep\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eComments:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water. Valve designed for cycling (not constantly powered on) applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eFrequency:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 50 Hz; 60 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eApprovals, Underwriters Laboratories Inc.:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e UL Listed: File MH11826\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eOperating \u003cst1:place\u003e\u003cst1:placename\u003eHumidity\u003c\/st1:placename\u003e \u003cst1:placetype\u003eRange\u003c\/st1:placetype\u003e\u003c\/st1:place\u003e (% RH):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 5 to 95% relative humidity, non-condensing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eVoltage:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 24 Vac; Power Consumption--7.7 VA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eTiming:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Nominal Open--15 sec\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eAmbient \u003cst1:place\u003e\u003cst1:placename\u003eTemperature\u003c\/st1:placename\u003e \u003cst1:placetype\u003eRange\u003c\/st1:placetype\u003e\u003c\/st1:place\u003e (F):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 125 F Maximum\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eAmbient Temperature Range (C):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 52 C Maximum\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eConnection Type:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Sweat\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eBody Pattern:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Two-way, Straight-through\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003ePipe Size (inch):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 1\/2 in.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003ePipe Size (DN):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e DN15\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eCurrent Draw:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 0.32A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eFluid Temperature (C):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 10 C to 93 C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eFluid Temperature (F):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 50 F to 200 F\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMaximum Differential Pressure Ratings (Close-off) (psi\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e): 20 psi\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMaximum Differential Pressure Ratings (Close-off) (kPa):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 138 kPa\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eElectrical Connections (in.):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 18 in. leads\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eElectrical Connections (mm):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 457 mm leads\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eCapacity (Cv):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 3.5 Cv\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eCapacity (Kv):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 3 Kv\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eValve Action:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Spring return to close\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eValve Type:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Zone Valve\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMaterials (Body):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Brass\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMaterials (Seat):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Brass\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMaterials (Stem):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Stainless Steel\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eEnd Switch Rating:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 50 VA pilot duty @ 24 V; 4.4 A running with 26.4 A inrush @ 120 V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eActuation:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Two position\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eDe-energized Position:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Normally Closed\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eAuxiliary End Switch:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e N.O. SPST\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eStatic Pressure Rating (psi):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 125 psi\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eStatic Pressure Rating (kPa):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e 862 kPa\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMaterials (Plug\/Ball\/Disc):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Buna-N (NBR) Rubber Ball\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMaterials (Packing):\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e EPDM O-rings\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eManual Opener:\u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e Yes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47344336470189,"sku":"V8043E1004","price":99.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/V8043E1004.jpg?v=1787907059","url":"https:\/\/www.bostonheatingsupply.com\/products\/honeywell-v8043e1004-1-2-sweat-zone-valve","provider":"Boston Heating Supply","version":"1.0","type":"link"}