{"product_id":"honeywell-vr8204a2076-intermittent-pilot-gas-valve","title":"Honeywell VR8204A2076 Intermittent Pilot Gas Valve","description":"\u003cspan style=\"font-size: small;\"\u003eHoneywell VR8204A2076 Intermittent Pilot Gas Valve\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003eSingle Stage, 24 Vac, Standard Opening, Intermittent Pilot Gas Valve. 1\/2 x 1\/2\". Set 3.5\" WC\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cdiv class=\"overview\"\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eCombination gas control for use in 24 Vac gas-fired, intermittent pilot appliances with capacities from 30 to 415 cfh.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"features\"\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.\u003c\/li\u003e\n\u003cli\u003eUse with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control Modules.\u003c\/li\u003e\n\u003cli\u003eCompact size.\u003c\/li\u003e\n\u003cli\u003eProvide two automatic valves.\u003c\/li\u003e\n\u003cli\u003eSolenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.\u003c\/li\u003e\n\u003cli\u003eDiaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.\u003c\/li\u003e\n\u003cli\u003eMeet codes requiring dual safety shutoff.\u003c\/li\u003e\n\u003cli\u003eNatural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.\u003c\/li\u003e\n\u003cli\u003eAll adjustments, wiring connections and pilot outlet are accessible from top of control.\u003c\/li\u003e\n\u003cli\u003eAdjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.\u003c\/li\u003e\n\u003cli\u003eCompatible with ECO connector.\u003c\/li\u003e\n\u003cli\u003eON-OFF lighting sequence.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eApplication: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003eSingle Stage\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eDimensions (in.): \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e4 5\/8 in. high x 4 1\/8 in. wide x 2 11\/16 in. deep\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eDimensions (mm): \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e117 mm high x 104 mm wide x 69 mm deep\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eIncludes: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003eNatural to LP Conversion Kit; One 1\/2\" x 3\/8\" reducer bushing; One 3\/4\" straight flange\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eMounting: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eFrequency: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e60 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eApprovals, Underwriters Laboratories Inc.: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003eUL Component Recognized MCCZ2.MH5323\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eApprovals, CSA: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003eCSA International: 112395\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eElectrical Connections: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e1\/4 in. quick-connect male terminals\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eVoltage: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e24 Vac\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eOperating \u003cst1:place\u003e\u003cst1:placename\u003eTemperature\u003c\/st1:placename\u003e \u003cst1:placetype\u003eRange\u003c\/st1:placetype\u003e\u003c\/st1:place\u003e (F): \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e0 F to 175 F\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eOperating Temperature Range (C): \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e-18 C to +79 C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eBody Pattern: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003eStraight-through\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eOpening Characteristics: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003eStandard\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003ePressure Ratings (psi): \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e1\/2 psi\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003ePressure Ratings (kPa): \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e3.5 kPa\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eInlet\/Outlet Size (in.): \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e1\/2 in. x 1\/2 in.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003ePilot Gas Outlet: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003eCompression fitting for 1\/4 in. OD tubing\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003ePressure Tapping: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e1\/8 in. NPT with plug\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eType of Fuel: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003eNatural (LP with included conversion kit)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eCapacity (kBtuh): \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003eAt 1 in. wc p.d.-- 150,000 BTUh: 20,000 BTUh minimum: 200,000 BTUh maximum Natural Gas\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eApprovals, Australian Gas Association: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e4752\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003ePressure Regulator: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003eStandard\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003ePressure Regulator Setpoint (in. wc): \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e3.5 in. wc\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003ePressure Regulator Setpoint (kPa): \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003e0.87 kPa\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"font-size: 12px;\"\u003eIgnition Type: \u003c\/b\u003e\u003cspan style=\"font-size: 12px;\"\u003eIntermittent Pilot\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47344336011437,"sku":"VR8204A2076","price":161.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/VR8204A2076.jpg?v=1787907054","url":"https:\/\/www.bostonheatingsupply.com\/products\/honeywell-vr8204a2076-intermittent-pilot-gas-valve","provider":"Boston Heating Supply","version":"1.0","type":"link"}