{"product_id":"honeywell-vr8300a4516-standing-pilot-gas-valve","title":"Honeywell VR8300A4516 Standing Pilot Gas Valve","description":"\u003cdiv class=\"overview\"\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCombination gas control for use in 24 Vac gas-fired, standing pilot appliances with capacities from 30 to 300 cfh.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"features\"\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eControl includes safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.\u003c\/li\u003e\n\u003cli\u003eCompact size.\u003c\/li\u003e\n\u003cli\u003eProvides two automatic valves.\u003c\/li\u003e\n\u003cli\u003eSolenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends.\u003c\/li\u003e\n\u003cli\u003eDiaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.\u003c\/li\u003e\n\u003cli\u003eMeets codes requiring dual safety shut-off.\u003c\/li\u003e\n\u003cli\u003eNatural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.\u003c\/li\u003e\n\u003cli\u003eAll adjustments, wiring connections and pilot outlet are accessible from top of control.\u003c\/li\u003e\n\u003cli\u003eAdjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.\u003c\/li\u003e\n\u003cli\u003eCompatible with ECO connector.\u003c\/li\u003e\n\u003cli\u003eLITE-RITE (OFF-PILOT-ON) lighting sequence.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cdiv class=\"specs\"\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; font-size: small;\"\u003e\u003cstrong\u003eProduct Specifications\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eApplication:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px; font-weight: normal;\"\u003eSingle Stage\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eDimensions (in.):\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e5 3\/8 in. high x 4 1\/16 in. wide x 2 11\/16 in. deep\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eDimensions (mm):\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e135 mm high x 104 mm wide x 69 mm deep\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eIncludes:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003eQ340 Thermocouple; Natural to LP conversion kit; Two 3\/4\" x 1\/2\" reducer bushings; ECO adaptor\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eMounting:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eFrequency:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e60 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eApprovals, Underwriters Laboratories Inc.:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003eUL Component Recognized MCCZ2.MH5323\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eApprovals, CSA:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003eCSA International: 112395\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eElectrical Connections:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e1\/4 in. quick-connect male terminals\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eVoltage:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e24 Vac\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eOperating Temperature Range (F):\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e0 F to 175 F\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eOperating Temperature Range (C):\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e-18 C to +79 C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eBody Pattern:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003eStraight-through with flange\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eOpening Characteristics:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003eStandard\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003ePressure Ratings (psi):\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e1\/2 psi\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003ePressure Ratings (kPa):\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e3.5 kPa\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eInlet\/Outlet Size (in.):\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e3\/4 in. x 3\/4 in.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003ePilot Gas Outlet:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003eCompression fitting for 1\/4 in. OD tubing\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003ePressure Tapping:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e1\/8 in. NPT with plug\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eType of Fuel:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003eNatural (LP with included conversion kit)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eCapacity (kBtuh):\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003eAt 1 in. wc p.d.-- 200,000 BTUh: 30,000 BTUh minimum: 300,000 BTUh maximum Natural Gas\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eApprovals, Australian Gas Association:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e4717\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003ePressure Regulator:\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003eStandard\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003ePressure Regulator Setpoint (in. wc):\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e3.5 in. WC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003ePressure Regulator Setpoint (kPa):\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e0.87 kPa\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 12px;\"\u003eIgnition Type\u003c\/strong\u003e\u003cspan style=\"font-size: 12px;\"\u003e: Standing Pilot\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47344375562413,"sku":"VR8300A4516","price":172.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/VR8300A3518.1.jpg?v=1787907345","url":"https:\/\/www.bostonheatingsupply.com\/products\/honeywell-vr8300a4516-standing-pilot-gas-valve","provider":"Boston Heating Supply","version":"1.0","type":"link"}