{"product_id":"laars-edp-110-endurance-hydronic-boiler","title":"Laars EDP 110 Endurance Hydronic Boiler","description":"\u003cspan style=\"font-size: 10pt; \"\u003eSpecifications:\u003cbr\u003e \u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eInput (MBTU\/h): 61.8-108.2\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eInput (kW): 18.1-31.7\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eOutput (MBTU\/h): 53.7-94.0\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eOutput (kW): 15.7-27.5\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eAFUE%: 85.5\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 10pt; \"\u003eMinimum Clearances from Combustible Materials:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eBack \u0026amp; Front: 1\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eSides: 1\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eTop (Alcove Install): 1\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eTop (Closet Install): 22\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eVent: Concentric, Direct: 0\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eVent: Category IV: 3\"\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-size: 10pt;\"\u003e\u003cspan style=\"font-size: 10pt; \"\u003eFeatures:\u003cbr\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eDesign certified and tested to ANSI standard Z21.13\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eDesigned and constructed in accordance with the ASME Boiler \u0026amp; Pressure Vessel Code, Sections II, IV, and IX\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eMaximum working pressure - water 30 psi, ASME rated\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eHydrostatic test pressure at factory - 60 psi\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eMinimum gas supply pressure - 4\" w.c.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eMaximum gas supply pressure - 13\" w.c.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003e85+% AFUE\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eSealed stainless steel combustion chamber\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eHot surface ignition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eAutomatic burner modulation from 57% to full fire\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eNOx levels less than 25 ppm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eVenting - Direct vent (sealed combustion with ducted combustion air in concentric vent) or Category III\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eDesign certified for installation directly on a combustible floor (except carpeting)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eOne-inch clearance on all 4 sides\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eZero clearance from combustibles to the vent when concentric venting is used\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eElectrical: 115V-60HZ-1PH less than 15 Amps with 24V transformer mounted and wired\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eOutdoor reset with the addition of outdoor air sensor (limited temperature range available for EBP models)\u003cbr\u003e \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eControl overrides outdoor reset when air sensor is faulty\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eEasy-to-use viewing and programming menus\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003e3-Character alphanumeric display of temperatures and fault codes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eDisplays fault codes for supply sensor, return sensor, tank sensor (EBP only), outdoor air sensor, internal control, and lockout\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eDisplays 6temperatures: supply water, return water, tank water (EBP only), heatexchanger temperature rise, outdoor air temperature (when outdoor resetis used), and calculated setpoint (when outdoor reset is used)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eControls LEDs indicated pump energized, attempt to ignite and gas valve energized\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eIgnition control LEDs show faults for erroneous flame signal, internal error and lockout\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eLow water temperature feature - attempts to run the pump when supply water temperature falls below 39°F\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eBuilt-in circulating pump and by-pass loop\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eEquipped with anti-condensing controls\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003ePump exerciser to ensure pump remains free from corrosion\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eBuilt-in safety limit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eCopper finned, cylindrical tube design heat exchanger brazed into ASME bronze headers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 10pt; \"\u003eEBP unitedstore 20 gallons of boiler water to provide instantaneous domestic hotwater production through a brazed plate heat exchanger, with DHWpriority\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cdiv\u003e\u003cspan style=\"font-size: 10pt; \"\u003e20 Year limited warranty\u003c\/span\u003e\u003c\/div\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e \u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eFor more information on this product please view the Sheet(s) below:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e \u003cbr\u003e  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Laars_Endurance_EBP_EDP_EDN_Installation_Manual.pdf\" target=\"_blank\"\u003eLaars Endurance EBP, EDP, EDN Installation Manual\u003c\/a\u003e\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Laars_Endurance_Parts_List.pdf\" target=\"_blank\"\u003eLaars Endurance Parts List\u003c\/a\u003e\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Laars_Endurance_Questions_And_Answers.pdf\" target=\"_blank\"\u003eLaars Endurance Questions And Answers Booklet\u003c\/a\u003e\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Laars","offers":[{"title":"Default Title","offer_id":47344020160685,"sku":"11722","price":2181.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/Endurancehydronic.8.jpg?v=1787900781","url":"https:\/\/www.bostonheatingsupply.com\/products\/laars-edp-110-endurance-hydronic-boiler","provider":"Boston Heating Supply","version":"1.0","type":"link"}