{"product_id":"renewaire-pbl-push-button-point-of-use-control","title":"RenewAire PBL Push Button Point-of-Use Control","description":"\u003cspan style=\"font-size: small;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/PB-L.pdf\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003cbr\u003eThe Push Button point-of-use control with indicator Light (PBL) works in conjunction with one Percentage\u003cbr\u003eTimer Control (PTL) and is compatible with RenewAire Energy Recovery Ventilator (ERV) models EV90\/P,\u003cbr\u003eEV130, EV200 and EV300. The PBL will operate your ERV for either 20, 40, or 60 minutes based upon\u003cbr\u003ehow many times the logo button has been pushed. The indicator light on the front of the PBL control is on\u003cbr\u003ewhenever the ERV is operating, unless operating due to an additional control wired directly to your ERV. The\u003cbr\u003ePBL control must be properly wired to a PTL control to operate the ERV.\u003cbr\u003e20-40-60 MINUTE VENTILATION CONTROL:\u003cbr\u003ePress the logo and your ventilator will run for 20 minutes. Press again and the unit will run 40 minutes. A third\u003cbr\u003epress provides for 60 minutes of operation. The PTL control does not need to be on for the PBL Control to\u003cbr\u003eoperate the ERV unit.\u003cbr\u003eYou can cancel a cycle at anytime. Just press the logo and hold for about five seconds.\u003cbr\u003eYou can start another cycle by pressing the logo.\u003cbr\u003eNOTE for ERV systems with more than one control:\u003cbr\u003eAnother control other than the push button may be causing your ventilator to run. If you wish to keep your\u003cbr\u003eventilator from running, check that none of your controls are calling for unit operation.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003cbr\u003e1. Attach two wires to the back of the PBL Control under the screws at the bottom. Tighten down the\u003cbr\u003escrews being careful not to over-tighten.\u003cbr\u003eWire Size: 18 - 22 gauge, no more than 500 feet. Wiring is non-polar.\u003cbr\u003e2. Install control in a standard 2” x 4” electrical box, with a minimum depth of 1.5”, with the two screws\u003cbr\u003eprovided.\u003cbr\u003e3. Two wires from the PBL Control should be attached to the ‘PB” positions on the terminal block on the\u003cbr\u003eback of the Percent Timer Control.\u003cbr\u003e4. For two PBL controls, one wire from each can be twisted together and inserted into a single position\u003cbr\u003eon the terminal block on the Percent Timer Control. The wires must be a maximum 18 gage solid wire.\u003cbr\u003eIf more than two PBL controls are attached or 18 gage stranded wire is used then pigtails must be\u003cbr\u003einserted into the ‘PB’ positions on the Percent Timer Control and the leads attached to the pigtails with\u003cbr\u003ewire nuts.\u003cbr\u003e5. Use Lutron Decora™ cover plate to complete installation (single cover plate included).\u003c\/p\u003e","brand":"RenewAire","offers":[{"title":"Default Title","offer_id":47344963551405,"sku":"PN 140480","price":40.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/PBL1.jpg?v=1787918970","url":"https:\/\/www.bostonheatingsupply.com\/products\/renewaire-pbl-push-button-point-of-use-control","provider":"Boston Heating Supply","version":"1.0","type":"link"}