{"product_id":"tpi-709-combustion-efficiency-analyzer-differential-manometer","title":"TPI 709 Combustion Efficiency Analyzer \u0026 Differential Manometer","description":"\u003cstrong style=\"\"\u003e709: Combustion Efficiency Analyzer and Differential Manometer\u003c\/strong\u003e\u003cspan style=\"\"\u003e \u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cul style=\"\"\u003e                      \u003cli\u003e            All the features of the 708 PLUS high resolution 0.001 in H20 \t\t\tdifferential manometer for high efficiency and oil equipment\u003c\/li\u003e                      \u003cli\u003e            Measure CO, and temperature\u003c\/li\u003e                      \u003cli\u003e            Calculate CO2, efficiency, excess air, and CO air free\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-weight: bold; \"\u003eSpecifications:\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cul style=\"\"\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eCarbon     Monoxide (CO) Measurement\u003c\/li\u003e          \u003cul type=\"circle\" style=\"margin-top: 0in;\"\u003e                    \u003cli style=\"\" class=\"MsoNormal\"\u003eRange      0 to 10,000 ppm\u003cbr\u003e                                    Resolution 1 ppm\u003cbr\u003e                                    Accuracy +\/-5ppm or 5% of reading whichever is greater\u003c\/li\u003e          \u003c\/ul\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eOxygen     (02) Measurement\u003c\/li\u003e          \u003cul type=\"circle\" style=\"margin-top: 0in;\"\u003e                    \u003cli style=\"\" class=\"MsoNormal\"\u003eRange      0 to 25%\u003cbr\u003e                                    Resolution 0.1%\u003cbr\u003e                                    Accuracy +\/-0.3%\u003c\/li\u003e          \u003c\/ul\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eCarbon     Dioxide (CO2)\u003c\/li\u003e          \u003cul\u003e                    \u003cli style=\"\" class=\"MsoNormal\"\u003eRange      0 to 25%\u003c\/li\u003e                    \u003cli style=\"\" class=\"MsoNormal\"\u003eResolution      0.1%\u003c\/li\u003e                    \u003cli style=\"\" class=\"MsoNormal\"\u003eCalculated      Value\u003c\/li\u003e          \u003c\/ul\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eTemperature     Measurement\u003c\/li\u003e          \u003cul type=\"circle\" style=\"margin-top: 0in;\"\u003e                    \u003cli class=\"MsoNormal\"\u003eRange      -40 to 1472F, or -40 to 800C \u003cbr\u003e                                    Resolution 1F or C\u003cbr\u003e                                    Accuracy (K-type) +\/-0.3%, +\/-2F or +\/-1C\u003c\/li\u003e          \u003c\/ul\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eDraft\/Pressure     Measurement\u003c\/li\u003e          \u003cul\u003e                    \u003cli style=\"\" class=\"MsoNormal\"\u003eSelectable      Ranges mBar,kPa, and inH2O\u003cbr\u003e                                    Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H20\u003cbr\u003e                                    Resolution 0.001 inH2O\u003cbr\u003e                                    Accuracy +\/-0\/5% fsd\u003c\/li\u003e          \u003c\/ul\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eGross\/Net     Efficiency\u003c\/li\u003e          \u003cul\u003e                    \u003cli style=\"\" class=\"MsoNormal\"\u003eRange      0 to 100%\u003cbr\u003e                                    Resolution 0.1%\u003cbr\u003e                                    Calculated Value\u003c\/li\u003e          \u003c\/ul\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eCO\/CO2     Ratio\u003c\/li\u003e          \u003cul\u003e                    \u003cli style=\"\" class=\"MsoNormal\"\u003eRange      0 to 0.999\u003cbr\u003e                                    Resolution 0.001\u003cbr\u003e                                    Calculated Value \u003c\/li\u003e          \u003c\/ul\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eOperating     Temperature: 14F to 122F (-10C to 50C)\u003c\/li\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eBattery Type: 1.5V AA (3)\u003c\/li\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eSelectable     Fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite     Coal, Coke, Butane, Wood, Bagasse\u003c\/li\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eDisplay     Type: Backlit 3 line LCD\u003c\/li\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eData     Storage: 50 Locations\u003c\/li\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003ePrint     Capability: Yes, via optional IR printer (A740)\u003c\/li\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eDate     \u0026amp; Time Function: 24 Hour Real Time Clock\u003c\/li\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eDimensions:     200mm x 90mm x 60mm\u003c\/li\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eWeight:     500g\u003c\/li\u003e          \u003cli style=\"\" class=\"MsoNormal\"\u003eConformity:     BS7927 (and the draft BS7967)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-weight: bold; \"\u003eApplications:\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003c!--[if gte mso 9]\u003e\u003cxml\u003e \u003cw:worddocument\u003e  \u003cw:view\u003eNormal\u003c\/w:view\u003e  \u003cw:zoom\u003e0\u003c\/w:zoom\u003e  \u003cw:punctuationkerning\u003e\u003c\/w:punctuationkerning\u003e  \u003cw:validateagainstschemas\u003e\u003c\/w:validateagainstschemas\u003e  \u003cw:saveifxmlinvalid\u003efalse\u003c\/w:saveifxmlinvalid\u003e  \u003cw:ignoremixedcontent\u003efalse\u003c\/w:ignoremixedcontent\u003e  \u003cw:alwaysshowplaceholdertext\u003efalse\u003c\/w:alwaysshowplaceholdertext\u003e  \u003cw:compatibility\u003e   \u003cw:breakwrappedtables\u003e\u003c\/w:breakwrappedtables\u003e   \u003cw:snaptogridincell\u003e\u003c\/w:snaptogridincell\u003e   \u003cw:wraptextwithpunct\u003e\u003c\/w:wraptextwithpunct\u003e   \u003cw:useasianbreakrules\u003e\u003c\/w:useasianbreakrules\u003e   \u003cw:dontgrowautofit\u003e\u003c\/w:dontgrowautofit\u003e  \u003c\/w:compatibility\u003e  \u003cw:browserlevel\u003eMicrosoftInternetExplorer4\u003c\/w:browserlevel\u003e \u003c\/w:worddocument\u003e\u003c\/xml\u003e\u003c![endif]--\u003e\u003c!--[if gte mso 9]\u003e\u003cxml\u003e \u003cw:latentstyles deflockedstate=\"false\" latentstylecount=\"156\"\u003e \u003c\/w:latentstyles\u003e\u003c\/xml\u003e\u003c![endif]--\u003e\u003c!--[if !mso]\u003e\u003cobject classid=\"clsid:38481807-CA0E-42D2-BF39-B33AF135CC4D\" id=\"ieooui\"\u003e\u003c\/object\u003e\u003cstyle\u003est1\\:*{behavior:url(#ieooui) }\u003c\/style\u003e\u003c![endif]--\u003e\u003c!--[if gte mso 10]\u003e\u003cstyle\u003e \/* Style Definitions *\/ table.MsoNormalTable\t{mso-style-name:\"Table Normal\";\tmso-tstyle-rowband-size:0;\tmso-tstyle-colband-size:0;\tmso-style-noshow:yes;\tmso-style-parent:\"\";\tmso-padding-alt:0in 5.4pt 0in 5.4pt;\tmso-para-margin:0in;\tmso-para-margin-bottom:.0001pt;\tmso-pagination:widow-orphan;\tfont-size:10.0pt;\t\"Times New Roman\";\tmso-ansi-language:#0400;\tmso-fareast-language:#0400;\tmso-bidi-language:#0400;}\u003c\/style\u003e\u003c![endif]--\u003e\u003cspan style=\"\"\u003e\u003c\/span\u003e\u003cul style=\"\"\u003e    \u003cli\u003eTuning of residential and furnaces and domestic boilers\u003c\/li\u003e    \u003cli\u003eAmbient and stack testing for CO\u003c\/li\u003e    \u003cli\u003eCO safety measurements in andaround combustion sources \u003cbr\u003e        \u003c\/li\u003e    \u003cli\u003eTemperature checking, including superheat andhydronic differential temperatures\u003c\/li\u003e    \u003cli\u003eDual input differential manometer\u003cbr\u003e        \u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"\"\u003e\u003c\/span\u003e\u003cspan style=\" font-weight: bold;\"\u003e\u003cbr\u003e    Resources:\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cul style=\"\"\u003e                      \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TPI_-_709_CombustionEfficiencyAnalyzer_-_ProductData.pdf\"\u003eTPI - 709 - Product Data\u003c\/a\u003e\u003c\/li\u003e                    \u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TPI_-_709_CombustionEfficiencyAnalyzer_-_Feature.pdf\"\u003eTPI - 709 - Features\u003c\/a\u003e\u003cbr\u003e                                        \u003c\/li\u003e                      \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TPI_-_709_CombustionEfficiencyAnalyzer_-_InstructionGuide.pdf\"\u003eTPI - 709 - Instruction Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"\"\u003e            \u003c\/span\u003e","brand":"TPI","offers":[{"title":"Default Title","offer_id":47344146251949,"sku":"56142","price":547.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/709_combustion_20analyzer.jpg?v=1787903738","url":"https:\/\/www.bostonheatingsupply.com\/products\/tpi-709-combustion-efficiency-analyzer-differential-manometer","provider":"Boston Heating Supply","version":"1.0","type":"link"}