{"product_id":"tpi-709a740c1-combustion-efficiency-analyzer-ir-printer-sulfer-filter","title":"TPI 709A740C1 Combustion Efficiency Analyzer, IR Printer, \u0026 Sulfer Filter","description":"\u003cstrong style=\"\"\u003e709 Combustion Efficiency Analyzer\u003c\/strong\u003e\u003cbr style=\"\"\u003e\u003cul style=\"\"\u003e  \u003cli\u003e            All the features of the 708 PLUS high resolution 0.001 in H20 \t\t\tdifferential manometer for high efficiency and oil equipment\u003c\/li\u003e  \u003cli\u003e            Measure CO, and temperature\u003c\/li\u003e  \u003cli\u003e            Calculate CO2, efficiency, excess air, and CO air free\u003c\/li\u003e\n\u003c\/ul\u003e\u003cem style=\"\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003cspan style=\"font-weight: bold; \"\u003eA740 Infrared Printer\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cul style=\"\"\u003e  \u003cli\u003eEasy to use\u003c\/li\u003e  \u003cli\u003eBattery operated\u003c\/li\u003e  \u003cli\u003eSelf test facility\u003c\/li\u003e  \u003cli\u003eAdjustable contrast\u003c\/li\u003e  \u003cli\u003eManual paper feed\u003c\/li\u003e  \u003cli\u003eMaximum transmitting distance 16\"(45cm)\u003c\/li\u003e  \u003cli\u003eCompatible with most other combustion analyzers\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\" font-weight: bold;\"\u003e773 Sulfur Filter\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cul\u003e  \u003cli\u003e\n\u003cspan style=\"\"\u003eFor oil work\u003c\/span\u003e\u003cbr\u003e    \u003c\/li\u003e\n\u003c\/ul\u003e \u003cbr\u003e\u003cspan style=\"font-weight: bold; \"\u003eSpecifications:\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cul style=\"\"\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eCarbon     Monoxide (CO) Measurement\u003c\/li\u003e  \u003cul type=\"circle\" style=\"margin-top: 0in;\"\u003e    \u003cli class=\"MsoNormal\" style=\"\"\u003eRange      0 to 10,000 ppm\u003cbr\u003e                                                                  Resolution 1 ppm\u003cbr\u003e                                                                  Accuracy +\/-5ppm or 5% of reading whichever is greater\u003c\/li\u003e  \u003c\/ul\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eOxygen     (02) Measurement\u003c\/li\u003e  \u003cul type=\"circle\" style=\"margin-top: 0in;\"\u003e    \u003cli class=\"MsoNormal\" style=\"\"\u003eRange      0 to 25%\u003cbr\u003e                                                                  Resolution 0.1%\u003cbr\u003e                                                                  Accuracy +\/-0.3%\u003c\/li\u003e  \u003c\/ul\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eCarbon     Dioxide (CO2)\u003c\/li\u003e  \u003cul\u003e    \u003cli class=\"MsoNormal\" style=\"\"\u003eRange      0 to 25%\u003c\/li\u003e    \u003cli class=\"MsoNormal\" style=\"\"\u003eResolution      0.1%\u003c\/li\u003e    \u003cli class=\"MsoNormal\" style=\"\"\u003eCalculated      Value\u003c\/li\u003e  \u003c\/ul\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eTemperature     Measurement\u003c\/li\u003e  \u003cul type=\"circle\" style=\"margin-top: 0in;\"\u003e    \u003cli class=\"MsoNormal\"\u003eRange      -40 to 1472F, or -40 to 800C \u003cbr\u003e                                                                  Resolution 1F or C\u003cbr\u003e                                                                  Accuracy (K-type) +\/-0.3%, +\/-2F or +\/-1C\u003c\/li\u003e  \u003c\/ul\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eDraft\/Pressure     Measurement\u003c\/li\u003e  \u003cul\u003e    \u003cli class=\"MsoNormal\" style=\"\"\u003eSelectable      Ranges mBar,kPa, and inH2O\u003cbr\u003e                                                                  Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H20\u003cbr\u003e                                                                  Resolution 0.001 inH2O\u003cbr\u003e                                                                  Accuracy +\/-0\/5% fsd\u003c\/li\u003e  \u003c\/ul\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eGross\/Net     Efficiency\u003c\/li\u003e  \u003cul\u003e    \u003cli class=\"MsoNormal\" style=\"\"\u003eRange      0 to 100%\u003cbr\u003e                                                                  Resolution 0.1%\u003cbr\u003e                                                                  Calculated Value\u003c\/li\u003e  \u003c\/ul\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eCO\/CO2     Ratio\u003c\/li\u003e  \u003cul\u003e    \u003cli class=\"MsoNormal\" style=\"\"\u003eRange      0 to 0.999\u003cbr\u003e                                                                  Resolution 0.001\u003cbr\u003e                                                                  Calculated Value \u003c\/li\u003e  \u003c\/ul\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eOperating     Temperature: 14F to 122F (-10C to 50C)\u003c\/li\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eBattery Type: 1.5V AA (3)\u003c\/li\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eSelectable     Fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite     Coal, Coke, Butane, Wood, Bagasse\u003c\/li\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eDisplay     Type: Backlit 3 line LCD\u003c\/li\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eData     Storage: 50 Locations\u003c\/li\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003ePrint     Capability: Yes, via optional IR printer (A740)\u003c\/li\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eDate     \u0026amp; Time Function: 24 Hour Real Time Clock\u003c\/li\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eDimensions:     200mm x 90mm x 60mm\u003c\/li\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eWeight:     500g\u003c\/li\u003e  \u003cli class=\"MsoNormal\" style=\"\"\u003eConformity:     BS7927 (and the draft BS7967)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-weight: bold; \"\u003eApplications:\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"\"\u003e\u003c\/span\u003e\u003cul style=\"\"\u003e  \u003cli\u003eTuning of residential and furnaces and domestic boilers\u003c\/li\u003e  \u003cli\u003eAmbient and stack testing for CO\u003c\/li\u003e  \u003cli\u003eCO safety measurements in andaround combustion sources \u003cbr\u003e                            \u003c\/li\u003e  \u003cli\u003eTemperature checking, including superheat andhydronic differential temperatures\u003c\/li\u003e  \u003cli\u003eDual input differential manometer\u003cbr\u003e                            \u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"\"\u003e\u003c\/span\u003e\u003cspan style=\" font-weight: bold;\"\u003e\u003cbr\u003e              Resources:\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cul style=\"\"\u003e  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TPI_-_709_CombustionEfficiencyAnalyzer_-_ProductData.pdf\"\u003eTPI - 709 - Product Data\u003c\/a\u003e\u003c\/li\u003e  \u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TPI_-_709_CombustionEfficiencyAnalyzer_-_Feature.pdf\"\u003eTPI - 709 - Features\u003c\/a\u003e\u003cbr\u003e                                                            \u003c\/li\u003e  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TPI_-_709_CombustionEfficiencyAnalyzer_-_InstructionGuide.pdf\"\u003eTPI - 709 - Instruction Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr style=\"\"\u003e\u003cspan style=\"\"\u003e            \u003c\/span\u003e","brand":"TPI","offers":[{"title":"Default Title","offer_id":47344146317485,"sku":"56105","price":690.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/709_combustionanalyzer.jpg?v=1787903739","url":"https:\/\/www.bostonheatingsupply.com\/products\/tpi-709a740c1-combustion-efficiency-analyzer-ir-printer-sulfer-filter","provider":"Boston Heating Supply","version":"1.0","type":"link"}