{"product_id":"tpi-ez100-easy-one-button-operation-dmm-56364","title":"TPI EZ100 Easy One Button Operation DMM 56364","description":"\u003cspan style=\"font-weight: bold; \"\u003eTPI EZ100 Easy One Button Operation DMM:\u003cbr\u003e \u003c\/span\u003e\u003cbr style=\"\"\u003e \u003cstrong style=\"\"\u003eNo more guessing what range to switch your meter to the TPI 100 does it automatically!\u003c\/strong\u003e\u003cul style=\"\"\u003e\n\u003cli\u003eAutomatically switches between ACV, DCV, and ohms (resistance).\u003c\/li\u003e\n\u003cul\u003e\u003cli\u003eBenefit: Simple to use. Meter selects function and range, just connect the leads to the device under test.\u003c\/li\u003e\u003c\/ul\u003e\n\u003cli\u003eSingle button operation.\u003c\/li\u003e\n\u003cul\u003e\u003cli\u003eBenefit: EZ to use. Enables users with limited knowledge to perform tests safely.\u003c\/li\u003e\u003c\/ul\u003e\n\u003cli\u003e0 to 600 volts AC and DC\u003c\/li\u003e\n\u003cul\u003e\u003cli\u003e Benefit: Enough range to safely perform measurements\u003c\/li\u003e\u003c\/ul\u003e\n\u003cli\u003e10 M internal impedance.\u003c\/li\u003e\n\u003cul\u003e\u003cli\u003eBenefit: High impedance prevents inaccurate reading caused by circuit loading.\u003c\/li\u003e\u003c\/ul\u003e\n\u003cli\u003eAuto power off.\u003c\/li\u003e\n\u003cul\u003e\u003cli\u003eBenefit: Increases battery life by turning off the multimeter when not in use.\u003c\/li\u003e\u003c\/ul\u003e\n\u003cli\u003e4,000 count display\u003c\/li\u003e\n\u003cli\u003eUp to 40M\u003c\/li\u003e\n\u003cli\u003ecULus 61010-1\u003c\/li\u003e\n\u003cli\u003eCAT II 1,000-V \/ CATIII 600V\u003c\/li\u003e\n\u003cli\u003e3 Year Limited Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-weight: bold; \"\u003eSpecifications:\u003c\/span\u003e\u003cbr style=\"\"\u003e \u003c!--[if gte mso 9]\u003e\u003cxml\u003e \u003cw:worddocument\u003e  \u003cw:view\u003eNormal\u003c\/w:view\u003e  \u003cw:zoom\u003e0\u003c\/w:zoom\u003e  \u003cw:punctuationkerning\u003e\u003c\/w:punctuationkerning\u003e  \u003cw:validateagainstschemas\u003e\u003c\/w:validateagainstschemas\u003e  \u003cw:saveifxmlinvalid\u003efalse\u003c\/w:saveifxmlinvalid\u003e  \u003cw:ignoremixedcontent\u003efalse\u003c\/w:ignoremixedcontent\u003e  \u003cw:alwaysshowplaceholdertext\u003efalse\u003c\/w:alwaysshowplaceholdertext\u003e  \u003cw:compatibility\u003e   \u003cw:breakwrappedtables\u003e\u003c\/w:breakwrappedtables\u003e   \u003cw:snaptogridincell\u003e\u003c\/w:snaptogridincell\u003e   \u003cw:wraptextwithpunct\u003e\u003c\/w:wraptextwithpunct\u003e   \u003cw:useasianbreakrules\u003e\u003c\/w:useasianbreakrules\u003e   \u003cw:dontgrowautofit\u003e\u003c\/w:dontgrowautofit\u003e  \u003c\/w:compatibility\u003e  \u003cw:browserlevel\u003eMicrosoftInternetExplorer4\u003c\/w:browserlevel\u003e \u003c\/w:worddocument\u003e\u003c\/xml\u003e\u003c![endif]--\u003e \u003c!--[if gte mso 9]\u003e\u003cxml\u003e \u003cw:latentstyles deflockedstate=\"false\" latentstylecount=\"156\"\u003e \u003c\/w:latentstyles\u003e\u003c\/xml\u003e\u003c![endif]--\u003e \u003c!--[if !mso]\u003e\u003cobject classid=\"clsid:38481807-CA0E-42D2-BF39-B33AF135CC4D\" id=\"ieooui\"\u003e\u003c\/object\u003e\u003cstyle\u003est1\\:*{behavior:url(#ieooui) }\u003c\/style\u003e\u003c![endif]--\u003e \u003c!--[if gte mso 10]\u003e\u003cstyle\u003e \/* Style Definitions *\/ table.MsoNormalTable\t{mso-style-name:\"Table Normal\";\tmso-tstyle-rowband-size:0;\tmso-tstyle-colband-size:0;\tmso-style-noshow:yes;\tmso-style-parent:\"\";\tmso-padding-alt:0in 5.4pt 0in 5.4pt;\tmso-para-margin:0in;\tmso-para-margin-bottom:.0001pt;\tmso-pagination:widow-orphan;\tfont-size:10.0pt;\t\"Times New Roman\";\tmso-ansi-language:#0400;\tmso-fareast-language:#0400;\tmso-bidi-language:#0400;}\u003c\/style\u003e\u003c![endif]--\u003e\u003cul style=\"\"\u003e\n\u003cli\u003eDC Volts:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum Input: 600V (Minimum Input = 1.5V)\u003c\/li\u003e\n\u003cli\u003eMaximum Resolution: 0.001V\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/-0.5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eAC Volts:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum Input: 600V (Minimum Input = 1.7V)\u003c\/li\u003e\n\u003cli\u003eMaximum Resolution: 0.001V\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/-0.8%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eResistance (Ohms):\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum Input: 40M\u003c\/li\u003e\n\u003cli\u003eMaximum Resolution: 0.1\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/-0.8%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eTrue RMS Responding: No\u003c\/li\u003e\n\u003cli\u003eConductance: No\u003c\/li\u003e\n\u003cli\u003ePulse Width: No\u003c\/li\u003e\n\u003cli\u003eData Hold: No\u003c\/li\u003e\n\u003cli\u003eMin\/Max Record: No\u003c\/li\u003e\n\u003cli\u003eTime Stamp Logging: No\u003c\/li\u003e\n\u003cli\u003eRelative Mode: No\u003c\/li\u003e\n\u003cli\u003eCompare Mode: No\u003c\/li\u003e\n\u003cli\u003eRS-232 Output: No\u003c\/li\u003e\n\u003cli\u003eProcess Loop Output: No\u003c\/li\u003e\n\u003cli\u003eSleep Mode \/ Auto Off No\u003c\/li\u003e\n\u003cli\u003eProtective Boot: Yes (standard)\u003c\/li\u003e\n\u003cli\u003eDisplay Type: 4000 count LCD\u003c\/li\u003e\n\u003cli\u003eRange Selection: Auto including function selection\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 32 F to 104 F (0 C to 40 C)\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: 14 F to 122 F (-10 C to 50 C)\u003c\/li\u003e\n\u003cli\u003eHumidity: 80% non-condensing\u003c\/li\u003e\n\u003cli\u003eSize: 6 x 3.1 x 1.2 (187mm x 86mm x 33mm) with boot\u003c\/li\u003e\n\u003cli\u003eWeight: 12oz (340g) with boot\u003c\/li\u003e\n\u003cli\u003eBattery Type: 1.5V AA Alkaline (2)\u003c\/li\u003e\n\u003cli\u003eBattery Life 500hrs Typical\u003c\/li\u003e\n\u003cli\u003eOvervoltage Category: CAT III 600V\u003c\/li\u003e\n\u003cli\u003eAgency Approval: IEC 1010-1\u003c\/li\u003e\n\u003cli\u003eWarranty: 3 Years\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-weight: bold; \"\u003eApplications:\u003c\/span\u003e\u003cbr style=\"\"\u003e \u003c!--[if gte mso 9]\u003e\u003cxml\u003e \u003cw:worddocument\u003e  \u003cw:view\u003eNormal\u003c\/w:view\u003e  \u003cw:zoom\u003e0\u003c\/w:zoom\u003e  \u003cw:punctuationkerning\u003e\u003c\/w:punctuationkerning\u003e  \u003cw:validateagainstschemas\u003e\u003c\/w:validateagainstschemas\u003e  \u003cw:saveifxmlinvalid\u003efalse\u003c\/w:saveifxmlinvalid\u003e  \u003cw:ignoremixedcontent\u003efalse\u003c\/w:ignoremixedcontent\u003e  \u003cw:alwaysshowplaceholdertext\u003efalse\u003c\/w:alwaysshowplaceholdertext\u003e  \u003cw:compatibility\u003e   \u003cw:breakwrappedtables\u003e\u003c\/w:breakwrappedtables\u003e   \u003cw:snaptogridincell\u003e\u003c\/w:snaptogridincell\u003e   \u003cw:wraptextwithpunct\u003e\u003c\/w:wraptextwithpunct\u003e   \u003cw:useasianbreakrules\u003e\u003c\/w:useasianbreakrules\u003e   \u003cw:dontgrowautofit\u003e\u003c\/w:dontgrowautofit\u003e  \u003c\/w:compatibility\u003e  \u003cw:browserlevel\u003eMicrosoftInternetExplorer4\u003c\/w:browserlevel\u003e \u003c\/w:worddocument\u003e\u003c\/xml\u003e\u003c![endif]--\u003e \u003c!--[if gte mso 9]\u003e\u003cxml\u003e \u003cw:latentstyles deflockedstate=\"false\" latentstylecount=\"156\"\u003e \u003c\/w:latentstyles\u003e\u003c\/xml\u003e\u003c![endif]--\u003e \u003c!--[if gte mso 10]\u003e\u003cstyle\u003e \/* Style Definitions *\/ table.MsoNormalTable\t{mso-style-name:\"Table Normal\";\tmso-tstyle-rowband-size:0;\tmso-tstyle-colband-size:0;\tmso-style-noshow:yes;\tmso-style-parent:\"\";\tmso-padding-alt:0in 5.4pt 0in 5.4pt;\tmso-para-margin:0in;\tmso-para-margin-bottom:.0001pt;\tmso-pagination:widow-orphan;\tfont-size:10.0pt;\t\"Times New Roman\";\tmso-ansi-language:#0400;\tmso-fareast-language:#0400;\tmso-bidi-language:#0400;}\u003c\/style\u003e\u003c![endif]--\u003e \u003cspan style=\"\"\u003e \u003c\/span\u003e\u003cul style=\"\"\u003e\n\u003cli\u003eMeasure line and control circuit voltages\u003c\/li\u003e\n\u003cli\u003eMeasure resistance of motor windings, transformers, and solenoids\u003c\/li\u003e\n\u003cli\u003eMake general AC and DC voltage and resistance measurements\u003c\/li\u003e\n\u003cli\u003eMeasure the resistance of elements and electric heater cores\u003c\/li\u003e\n\u003cli\u003eTest continuity of wiring Verify voltage at breakers and outlets\u003c\/li\u003e\n\u003cli\u003e Use as a back-up meter in your tool box\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"\"\u003e \u003c\/span\u003e \u003cspan style=\"font-weight: bold; \"\u003eResources:\u003c\/span\u003e\u003cbr style=\"\"\u003e\u003cul style=\"\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TPI_-_EZ100_Multimeter_-_ProductData.pdf\"\u003eTPI - EZ100 - Product Data\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/TPI_-_EZ100_Multimeter_-_InstructionGuide.pdf\"\u003eTPI - EZ100 - Instruction Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr style=\"\"\u003e \u003cspan style=\"\"\u003e \u003c\/span\u003e","brand":"TPI","offers":[{"title":"Default Title","offer_id":47344146841773,"sku":"56364","price":53.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/5895\/3645\/files\/EZ100_EasyDMM.jpg?v=1787903772","url":"https:\/\/www.bostonheatingsupply.com\/products\/tpi-ez100-easy-one-button-operation-dmm-56364","provider":"Boston Heating Supply","version":"1.0","type":"link"}