709 Combustion Efficiency Analyzer
Specifications:
Resources:
- All the features of the 708 PLUS high resolution 0.001 in H20 differential manometer for high efficiency and oil equipment
- Measure CO, and temperature
- Calculate CO2, efficiency, excess air, and CO air free
- Easy to use
- Battery operated
- Self test facility
- Adjustable contrast
- Manual paper feed
- Maximum transmitting distance 16"(45cm)
- Compatible with most other combustion analyzers
-
For oil work
Specifications:
- Carbon Monoxide (CO) Measurement
- Range 0 to 10,000 ppm
Resolution 1 ppm
Accuracy +/-5ppm or 5% of reading whichever is greater - Oxygen (02) Measurement
- Range 0 to 25%
Resolution 0.1%
Accuracy +/-0.3% - Carbon Dioxide (CO2)
- Range 0 to 25%
- Resolution 0.1%
- Calculated Value
- Temperature Measurement
- Range -40 to 1472F, or -40 to 800C
Resolution 1F or C
Accuracy (K-type) +/-0.3%, +/-2F or +/-1C - Draft/Pressure Measurement
- Selectable Ranges mBar,kPa, and inH2O
Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H20
Resolution 0.001 inH2O
Accuracy +/-0/5% fsd - Gross/Net Efficiency
- Range 0 to 100%
Resolution 0.1%
Calculated Value - CO/CO2 Ratio
- Range 0 to 0.999
Resolution 0.001
Calculated Value - Operating Temperature: 14F to 122F (-10C to 50C)
- Battery Type: 1.5V AA (3)
- Selectable Fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
- Display Type: Backlit 3 line LCD
- Data Storage: 50 Locations
- Print Capability: Yes, via optional IR printer (A740)
- Date & Time Function: 24 Hour Real Time Clock
- Dimensions: 200mm x 90mm x 60mm
- Weight: 500g
- Conformity: BS7927 (and the draft BS7967)
- Tuning of residential and furnaces and domestic boilers
- Ambient and stack testing for CO
- CO safety measurements in andaround combustion sources
- Temperature checking, including superheat andhydronic differential temperatures
- Dual input differential manometer
Resources: